Optimizing accuracy of freehand cannulation of the ipsilateral ventricle for intracranial pressure monitoring in patients with brain trauma

Zhongyi Sun, Lin Wu, Zhixiong Liu, Weiming Zhong, Zhifeng Kou, Jinfang Liu

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Background: Intracranial pressure (ICP) monitoring in traumatic brain injury (TBI) usually requires the placement of a catheter into the ipsilateral ventricle. This surgical procedure is commonly performed via a freehand method using surface anatomical landmarks as guides. The current accuracy of the catheter placement remains relatively low and even lower among TBI patients. This study was undertaken to optimize the freehand ventricular cannulation to increase the accuracy for TBI. The authors hypothesized that an optimal surgical plan of cannulation should give an operator the greatest degrees of freedom, which could be measured as the range of operation angle, range of catheter placement depth, and size of the target area. Methods: An imaging simulation was first performed using the computed tomography (CT) images of 47 adult patients with normal brain anatomy. On the reconstructed 3D head model, four different coronal planes of ventricular cannulation were identified: A 4-cm anterior, a 2-cm anterior, a standard (central), and a 2-cm posterior plane. The degrees of freedom during the cannulation procedure were determined, including the relevant angles, lengths of cannulation, cross-sectional area, and bounding rectangle of the lateral ventricle. Next, a retrospective assessment was performed on the CT scans of another 111 patients with TBI who underwent freehand ventricular cannulation for ICP monitoring. Postoperative measurements were also performed based on CT images to calculate the accuracy and safety of catheter placement between coronal planes in practice. Results: Our simulation results showed that the 2-cm anterior plane had more extensive degrees of freedom for ventricular cannulation, in terms of length of catheter trajectory (7% longer, P<0.001), cross-sectional area of the lateral ventricle (14% larger, P=0.046), and length of the lateral ventricle (17% wider, P<0.001) than that of the standard plane, while both the 4-cm anterior and 2-cm posterior planes did not offer advantages over the standard plane in these ways. The mean length range of catheter trajectory in the 2-cm anterior plane was 41 to 58 mm. Retrospective assessment of TBI patients with ICP monitor placement also confirmed our simulation data. It showed that the accuracy of ipsilateral ventricle cannulation in the 2-cm anterior plane was 70.6%, which was a significant increase from 42.9% in the standard plane (P=0.007). Conclusions: Our imaging simulation and retrospective study demonstrate that different coronal planes could provide different degrees of freedom for cannulation, the 2-cm anterior plane has the greatest degrees of freedom in terms of larger target area and greater length range of the trajectory. The optimized surgical plan in this manner could improve cannulation accuracy and benefit a significant number of TBI patients.

Original languageEnglish (US)
Pages (from-to)2144-2156
Number of pages13
JournalQuantitative Imaging in Medicine and Surgery
Volume10
Issue number11
DOIs
StatePublished - Nov 2020
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Keywords

  • Intracranial pressure (ICP)
  • Surgical simulation
  • Traumatic brain injury (TBI)
  • Ventricular cannulation

Fingerprint

Dive into the research topics of 'Optimizing accuracy of freehand cannulation of the ipsilateral ventricle for intracranial pressure monitoring in patients with brain trauma'. Together they form a unique fingerprint.

Cite this