TY - JOUR
T1 - Signal and charge enhancement for protein analysis by liquid chromatography-mass spectrometry with desorption electrospray ionization
AU - Liu, Yan
AU - Miao, Zhixin
AU - Lakshmanan, Rajeswari
AU - Loo, Rachel R.Ogorzalek
AU - Loo, Joseph A.
AU - Chen, Hao
N1 - Funding Information:
The financial supports of this work by NSF ( CHE-0911160 ) and NSF Career ( CHE-1149367 ) to H.C. and by NIH ( R01 RR020004 , now reassigned as GM103479 ) to J.A.L. are gratefully acknowledged.
PY - 2012/7/1
Y1 - 2012/7/1
N2 - We recently reported the use of desorption electrospray ionization (DESI) as a novel interface to couple high-performance liquid chromatography (HPLC) with mass spectrometry (MS) (Chem. Commun. 47 (2011) 4171). One of the benefits of such an interface is that post-column derivatization of separated analytes can be integrated with ionization via a "reactive" DESI approach in which a derivatizing reagent is doped into the spray solvent. The reactive DESI interface allows analyte desorption/ionization from the end of the chromatographic column with prompt MS detection; a short time delay of ∼20 ms was demonstrated. In this study, we extended this application by "supercharging" proteins following HPLC separation using a DESI spray solvent containing supercharging reagents, m-nitrobenzyl alcohol (m-NBA) or sulfolane. Proteins (insulin, ubiquitin, lysozyme and α-lactalbumin) eluted out of the LC column can be supercharged with the protein charge state distributions (CSDs) significantly increased (to higher charge), which would be advantageous for subsequent top-down MS analysis of proteins. Interestingly, supercharging combined with reactive DESI enhances tolerance towards trifluoroacetic acid (TFA), which is known to be a superior additive in the mobile phase for premium peptide/protein chromatographic separation but has severe signal suppression effects for conventional electrospray ionization (ESI). In comparison to electrosonic spray ionization (ESSI), a variant form of ESI, the sensitivity of protein analysis using LC/DESI-MS with the mobile phase containing TFA can be improved by up to 70-fold for lysozyme and α-lactalbumin by including m-NBA in the DESI spray solvent. Presumably, by reducing TFA dissociation in the droplet, supercharging agents lower trifluoroacetate anion concentrations and concomitantly reduce ion pairing to analyte cationic sites. The reduced ion pairing therefore decreases the TFA signal suppression effect. The supercharging capability and the reduction of TFA signal suppression suggest that LC/DESI-MS is a valuable method for protein analysis.
AB - We recently reported the use of desorption electrospray ionization (DESI) as a novel interface to couple high-performance liquid chromatography (HPLC) with mass spectrometry (MS) (Chem. Commun. 47 (2011) 4171). One of the benefits of such an interface is that post-column derivatization of separated analytes can be integrated with ionization via a "reactive" DESI approach in which a derivatizing reagent is doped into the spray solvent. The reactive DESI interface allows analyte desorption/ionization from the end of the chromatographic column with prompt MS detection; a short time delay of ∼20 ms was demonstrated. In this study, we extended this application by "supercharging" proteins following HPLC separation using a DESI spray solvent containing supercharging reagents, m-nitrobenzyl alcohol (m-NBA) or sulfolane. Proteins (insulin, ubiquitin, lysozyme and α-lactalbumin) eluted out of the LC column can be supercharged with the protein charge state distributions (CSDs) significantly increased (to higher charge), which would be advantageous for subsequent top-down MS analysis of proteins. Interestingly, supercharging combined with reactive DESI enhances tolerance towards trifluoroacetic acid (TFA), which is known to be a superior additive in the mobile phase for premium peptide/protein chromatographic separation but has severe signal suppression effects for conventional electrospray ionization (ESI). In comparison to electrosonic spray ionization (ESSI), a variant form of ESI, the sensitivity of protein analysis using LC/DESI-MS with the mobile phase containing TFA can be improved by up to 70-fold for lysozyme and α-lactalbumin by including m-NBA in the DESI spray solvent. Presumably, by reducing TFA dissociation in the droplet, supercharging agents lower trifluoroacetate anion concentrations and concomitantly reduce ion pairing to analyte cationic sites. The reduced ion pairing therefore decreases the TFA signal suppression effect. The supercharging capability and the reduction of TFA signal suppression suggest that LC/DESI-MS is a valuable method for protein analysis.
KW - Liquid chromatography-mass spectrometry
KW - Protein supercharging
KW - Reactive DESI
KW - TFA ion suppression
UR - http://www.scopus.com/inward/record.url?scp=84865471749&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84865471749&partnerID=8YFLogxK
U2 - 10.1016/j.ijms.2012.06.006
DO - 10.1016/j.ijms.2012.06.006
M3 - Article
AN - SCOPUS:84865471749
SN - 1387-3806
VL - 325-327
SP - 161
EP - 166
JO - International Journal of Mass Spectrometry
JF - International Journal of Mass Spectrometry
ER -