TY - JOUR
T1 - Simultaneous determination of four trace estrogens in feces, leachate, tap and groundwater using solid-liquid extraction/auto solid-phase extraction and high-performance liquid chromatography with fluorescence detection
AU - Liu, Na
AU - Shi, Yue E.
AU - Li, Mengyan
AU - Zhang, Ting Di
AU - Gao, Song
N1 - Publisher Copyright:
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
PY - 2015/10
Y1 - 2015/10
N2 - A simple and selective high-performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α-ethynyl estradiol) in environmental matrices. For feces samples, solid-liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid-phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed-phase C18 column gradient-eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10-2 (estrone), 4.11 × 10-4 (estradiol), 5.2 × 10-3 (estriol) and 7.18 × 10-3 μg/L (17α-ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2-105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area.
AB - A simple and selective high-performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α-ethynyl estradiol) in environmental matrices. For feces samples, solid-liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid-phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed-phase C18 column gradient-eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10-2 (estrone), 4.11 × 10-4 (estradiol), 5.2 × 10-3 (estriol) and 7.18 × 10-3 μg/L (17α-ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2-105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area.
KW - Estrogens
KW - Fluorescence detection
KW - High-performance liquid chromatography
KW - Solid-liquid extraction
KW - Solid-phase extraction
UR - http://www.scopus.com/inward/record.url?scp=84945482621&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84945482621&partnerID=8YFLogxK
U2 - 10.1002/jssc.201500443
DO - 10.1002/jssc.201500443
M3 - Article
C2 - 26248873
AN - SCOPUS:84945482621
SN - 1615-9306
VL - 38
SP - 3494
EP - 3501
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 20
ER -